4 5 2 5   A    MICROPOLIS
NO MORE PRODUCED                                      Native|  Translation
                                                      ------+-----+-----+-----
Form                 3.5"/SLIMLINE         Cylinders    6807| 4884|     |
Capacity form/unform  2500/      MB        Heads           4|   16|     |
Seek time   / track  10.5/     ms          Sector/track     |   63|     |
Controller           IDE / ATA3            Precompensation
Cache/Buffer               KB              Landing Zone
Data transfer rate   10.000 MB/S int       Bytes/Sector      512
                     16.600 MB/S ext
Recording method                                    operating  | non-operating
                                                  -------------+--------------
Supply voltage     5/12 V       Temperature *C                 |
Power: sleep              W     Humidity     %                 |
       standby            W     Altitude    km                 |
       idle           5.0 W     Shock        g                 |
       seek           6.0 W     Rotation   RPM      5200
       read/write         W     Acoustic   dBA
       spin-up            W     ECC        Bit
                                MTBF         h     400000
                                Warranty Month
Lift/Lock/Park     YES          Certificates                                  

**********************************************************************
                        L   A   Y   O   U   T
**********************************************************************
MICROPL. 4525/4540/4550A  JUMPER SETTING

  +---------------------------------------------------------+
  |                                                         |XX
  |                                                         |XXI
  |                                                         |XXN  J1C
  |                                                         |XXT
  |                                                         |XXE
  |                                                         |XXR
  |              Board-No. 133872                           |XXF
  |                                                         |XXA
  |                                                         |XXC
  |                                                         |XXE
  |                                                         |
  |                                                         |XX J1B
  |                                                         |XX
  |                           E++++A JP1                    |
  |                           ++++++                        |XX Power
  |                                                         |XX J1A
  +---------------------------------------------------------+







    +-------J1C----------1-+--1+---------+
    | ******************** |***|X X X X  |
    | ********** ********* |***|x x x x  |
    +-------|--------------+J1B+-Power---+
            + Pin 28



**********************************************************************
                      J   U   M   P   E   R   S
**********************************************************************
MICROPL. 4525/4540/4550A  JUMPER SETTING

 Jumper Setting
 ==============

    +-------J1C----------1-+--1+---------+
    | ******************** |***|X X X X  |
    | ********** ********* |***|x x x x  |
    +-------|--------------+J1B+-Power---+
            + Pin 28

 JP1 Slave Present Position C
 -----------------------------
 This option may be needed at system-level integration if the slave
 drive cannot be detected by the  master drive; i.e., if the interface
 signals identify the slave drive are not present

 - a jumper installed at position C indicates that the slave drive is
   present.

 - when the jumper is omitted at position C, the master drive detects
   the slave drive automatically by using signals DASP- and PDIAG-.


 JP1 Drive is Master Position D
 ------------------------------
 - A jumper installed at position D selects the drive as the master
   drive.

 - The jumper omitted at position D selects the drive as slave drive,


 JP1 Cable Select Option Position E
 ----------------------------------
    +-------J1C----------1-+-
    | ******************** |*
    | ********** ********* |
    +-------|--------------+
            + Pin 28

 - When a jumper is installed at position E, the signal level on
   Signal Connector pin 28 defines the drive as follows:

        A low (ground) at pin 28 sets the drive as a Master.
        A high (open) at pin 28 sets the drive as a Slave.

 - When the jumper is omitted at position E, master/slave selection
   is accomplished via JP1, position DD (DRIVE is MASTER Option).



**********************************************************************
                      I   N   S   T   A   L   L
**********************************************************************
MICROPL. 4525/4540/4550A  JUMPER SETTING

 Notes on installation
 =====================

 Installation direction
 ----------------------

     horizontally                           vertically
   +-----------------+             +--+                       +--+
   |                 |             |  +-----+           +-----+  |
   |                 |             |  |     |           |     |  |
 +-+-----------------+-+           |  |     |           |     |  |
 +---------------------+           |  |     |           |     |  |
                                   |  |     |           |     |  |
                                   |  |     |           |     |  |
                                   |  +-----+           +-----+  |
                                   +--+                       +--+

 The mounting screws must be selected so that they do not penetrate
 the bottom mounting holes by more than 0.20 inches or the side
 mounting holes by more than 0.156 inches. Screws that are too long
 may short to PCBA components.

 The 45x0A drive uses industry-standard mounting for 3.5-inch, 1-inch
 high, disk drives.

 Recommended orientation is vertical on either side, or horizontal
 with the Device Electronics board down; other mounting orientations
 may be used.

 No matter what the mounting orientation is used, Micropolis specifies